The Carbon Dividend of Right-Sizing
Internal study — September 11, 2026
Version: 1.1
Last updated: 2026-09-11
Abstract
Right-sizing — Elis's practice of routing each task to the smallest model
tier capable of doing it, rather than defaulting every prompt to a frontier
model — is documented elsewhere in this Whitepapers library as a token and
cost optimization. This note asks a narrower question: what does the same
token reduction imply for estimated CO2e emissions? We combine our own
measured token-avoidance ratios with externally published per-token energy
and grid carbon-intensity figures to produce a bounded estimate, not a
platform-measured footprint. Every energy and carbon figure below is
borrowed from external published sources, cited individually; only the
token-reduction percentages are our own measurements. Central estimate:
routing 1 million assistant prompts through Elis's measured 80% token
reduction avoids roughly 75 kg CO2e versus serving them all on a frontier
model — comparable to a few hundred kilometers of average passenger-car
driving. The range across scenarios spans roughly 30x, and the reasons for
that spread are the point of this paper as much as the headline number.
1. Background
Right-sizing means matching each task's actual capability requirement to
the smallest model tier that can serve it, instead of defaulting every
request to the most capable (and most compute-hungry) frontier model. Elis's
dynamic model scorer performs this routing at runtime, per CLAUDE.md
Non-Negotiable #1 (never hardcode a model) and #4 (keep orchestration
dynamic) — the platform selects capabilities, and a scorer binds the
concrete model only at execution time.
Elis has measured, on its own platform, that right-sizing meaningfully cuts
the number of tokens a frontier model would otherwise have had to generate
or process. Two independent measurements exist (see §2). This paper asks
what avoiding those frontier-model tokens is plausibly worth in CO2e,
building the estimate from external energy-per-token literature rather than
from any energy measurement Elis has made itself — the platform does not
instrument miner power draw, and no such claim is made here.
2. Methodology
Formula.
CO2e saved = frontier tokens avoided × ΔE_per_token × PUE factor × grid carbon intensity
Frontier tokens avoided is a measured ratio; the other three factors are
externally published estimates, combined explicitly below rather than
presented as one black-box number.
Per-token energy — frontier side. Google's production measurement of its
Gemini serving fleet reports a median 0.24 Wh per text prompt, already
inclusive of the fleet's measured Power Usage Effectiveness (PUE ≈ 1.09)
(Elkin et al., arXiv:2508.15734, Aug 2025; Google Cloud blog, "Measuring the
environmental impact of AI inference"). Converting a per-prompt figure to a
per-token figure requires an assumed prompt length; we use 750 tokens as the
midpoint of a 500–1,000 token band, giving:
0.24 Wh / 750 tokens ≈ 0.32 mWh/token (frontier central; band 0.24–0.48 mWh/token across the 500–1,000 token range)
Two independent figures corroborate this band: Epoch AI's estimate for
GPT-4o of roughly 0.3 Wh per query (IQR 0.16–0.60 Wh) (epoch.ai,
"How much energy does ChatGPT use?"), and OpenAI's own stated figure of
0.34 Wh per query. All three cluster around the same order of magnitude.
Per-token energy — small-model side. We deliberately do not use the
~40x energy gap Luccioni et al. measured between BLOOM-176B and a 7B model
(FAccT 2024, arXiv:2311.16863) as the small-model discount, because it is a
comparison of two specific historical models rather than a general
large-vs-small ratio, and current serving practice narrows it further:
MLPerf inference benchmarks show near-linear (not super-linear) energy
scaling with parameter count at fixed hardware, and production serving
techniques compress the gap further still — batching reduces per-query
energy by an estimated 25–55%, and quantization techniques (e.g. FP8)
enable further efficiency gains (MLPerf Power) (see arXiv:2505.09598 and
arXiv:2410.12032 for the batching and quantization measurements
respectively). We therefore use a conservative 1/10 reduction
in per-token energy for the small model relative to the frontier model —
deliberately smaller than the ~40x literature datapoint, so that this paper
understates rather than overstates the energy benefit of right-sizing:
ΔE_per_token (central) = 0.32 mWh/token frontier − 0.032 mWh/token small‑model ≈ 0.29 mWh/token avoided
PUE handling. The Google figure above is already facility-inclusive (it
bakes in Google's fleet PUE of ~1.09), so no additional PUE multiplier is
applied to it. The Luccioni et al. BLOOM figure, by contrast, is an IT-load
(compute-only) measurement, so the HIGH scenario below applies an explicit
PUE multiplier to it rather than double-counting or omitting facility
overhead.
Grid carbon-intensity scenarios. CO2e per frontier-token-avoided, by
scenario:
| Scenario | Grid intensity | Source | CO2e per token avoided |
|---|---|---|---|
| LOW | 384 gCO2/kWh (Ember 2024 actual, US grid average; 393 in 2023) | Ember, "US Electricity 2025 Special Report" | 0.11 mg |
| CENTRAL | 435 gCO2/kWh (world average grid) | IEA, "Electricity 2026" (emissions) | 0.125 mg |
| HIGH | 435 gCO2/kWh, applied to an older-literature energy figure (BLOOM ~4 Wh/query IT-load, ×1.54 industry-average PUE) | Luccioni et al. FAccT 2024 (arXiv:2311.16863); Uptime Institute 2025 PUE survey | 3.22 mg |
LOW and CENTRAL differ from each other only by grid carbon intensity —
same energy-per-token assumption, different regional grid mix. The LOW
figure uses Ember's actual 2024 US grid-average intensity (384 gCO2/kWh, up
from 393 in 2023); using the actual figure rather than an older, lower
estimate narrows, rather than widens, the gap between LOW and the
CENTRAL world-average estimate (435 gCO2/kWh). HIGH swaps in
an entirely different, older, larger, less-optimized reference system (an
IT-load-only measurement of a 176B-parameter model with an industry-average
PUE applied on top) rather than a different grid. The resulting ~26x spread
between CENTRAL and HIGH therefore reflects two compounding effects at
once — the 5–20x methodology gap documented across the published
energy-per-query literature, and genuine efficiency gains across model
generations (smaller, more optimized serving vs. an older large monolithic
model) — and is not a tight statistical confidence interval. Treat HIGH as
a deliberately conservative upper bound built from an older, worse-case
reference system, not as equally likely to the CENTRAL estimate.
Savings bases. Two independent, platform-measured token-avoidance ratios
are carried through side by side rather than collapsed into one number:
- 80% basis — measured on one real production account over 30 days,
reported (not projected). At a 750-token frontier prompt, this avoids
600 tokens per prompt. - 44.8% basis — fewer tokens measured across 508 of our own platform
plans (the same measurement underlying the separately reported 1.8x
quota-runway token ratio, p50 1.73x). At a 750-token frontier prompt,
this avoids 336 tokens per prompt.
Both are our own platform's measured token ratios; neither is a projection
or an externally sourced figure. See §5 for what these ratios do and do not
imply.
2.7 Toward per-run granularity: tier-resolved accounting
Motivation. The platform records, for every orchestration step, which
concrete model executed it and its token counts (CLAUDE.md Non-Negotiable
5 — trace everything). That trace already carries the information needed
to compute CO2e per run from the actual tier mix a run used, rather than
from the blanket small-model assumption in §2 above, which credits every
avoided frontier token to a single small-tier model regardless of which
tier actually served it.
Per-token energy vector. We extend the two-point (frontier / small)
energy comparison in §2 to three tiers:
E = (frontier: 0.32, small: 0.032, nano: 0.011) mWh/token
Frontier is derived as in §2. Small keeps the same conservative 1/10
reduction used throughout this paper (vs. the measured ~40x BLOOM
176B-vs-7B gap — see §2 and §4). Nano is an explicit, stated
assumption, set at 1/3 of the small-tier figure. That assumption is
consistent with, and bounded above by, the published GPT-4.1-nano figure of
under 0.5 Wh per prompt ("How Hungry is AI," arXiv:2505.09598) — but that
published figure is a loose per-prompt upper bound, not a per-token
measurement, so it constrains rather than confirms the 0.011 mWh/token
value used here.
Formulas.
CO2e_actual(run) = Σ over steps [ tokens_step × E(tier of executing model) × grid intensity ]
CO2e_counterfactual(run) = frontier-baseline tokens × E_frontier × grid intensity
savings(run) = CO2e_counterfactual(run) − CO2e_actual(run)
The blanket method used in §2–§3 is the special case of this formula where
every right-sized token is assumed to have run on the small tier; substituting
100% small-tier occupancy into CO2e_actual reproduces the §3 central
figure (0.125 mg CO2e per token avoided) exactly.
Illustrative table (ILLUSTRATIVE — assumed small/nano tier splits, not a
measured production mix). Central, 80%-basis, per-1,000,000-prompt figure
under increasing nano-tier share:
| Small / nano split | Per-1M-prompt CO2e (central) | vs. blanket (100/0) |
|---|---|---|
| 100 / 0 (blanket, §3) | 75 kg | — |
| 70 / 30 | ~77 kg | +2.3% |
| 50 / 50 | ~78 kg | +3.8% |
| 30 / 70 | ~79 kg | +5.3% |
Under these conservative tier factors, the granular method shifts the
central estimate only modestly (+2–5%) versus the blanket §3 figure; its
main value is precision and per-run auditability rather than a materially
different headline number. Because nano energy is assumed strictly lower
than small energy, tier-resolved accounting can only raise, never lower,
the blanket estimate.
A measured production tier mix will replace the illustrative splits above
once per-step token usage records are fully populated across the fleet;
until then, the published figures in this paper remain the blanket
(conservative) method of §2–§3.
A known conservative bias. Published measurements put frontier
reasoning models above 33 Wh per long prompt (same source, "How Hungry is
AI," arXiv:2505.09598) — far above the 0.24 Wh/prompt central frontier
figure used throughout this paper (derived from Google's Gemini serving
fleet, §2). Savings estimated against a reasoning-heavy frontier baseline
are therefore understated by this paper's method.
3. Results
All figures rounded to 2 significant figures.
Per 1,000,000 assistant prompts (frontier-token-avoidance basis ×
per-token CO2e scenario):
| Basis | LOW | CENTRAL | HIGH |
|---|---|---|---|
| 80% tokens avoided | 66 kg | 75 kg | 1.9 t |
| 44.8% tokens avoided | — | 42 kg | — |
(The 44.8% basis is reported at CENTRAL only, to avoid presenting six
numbers where the two savings bases are meant to bracket a range, not
multiply one.)
Equivalence, CENTRAL / 80% basis. 75 kg CO2e is comparable to roughly
300–440 km of average passenger-car driving in the US, using the EPA's
published average passenger-vehicle emissions figure of about 400 g CO2e
per mile (~250 g/km US-specific) alongside a broader global average vehicle
band of 170–192 g/km; we present a range rather than one figure because the
per-km factor itself varies by vehicle mix and geography (EPA,
"Greenhouse Gas Emissions from a Typical Passenger Vehicle").
Illustrative organization. A 50-seat organization at 20 prompts/seat/day
for 30 days is 30,000 prompts/month — this volume assumption is
illustrative, not measured; no claim is made that any actual customer
account matches this shape. At that illustrative volume:
| Basis | CENTRAL | HIGH |
|---|---|---|
| 80% tokens avoided | 2.3 kg/month | 58 kg/month |
| 44.8% tokens avoided | 1.3 kg/month | — |
4. Sensitivity & limitations
- The CENTRAL-to-HIGH spread (~26x) is not a confidence interval. It
mixes a documented 5–20x methodology gap in the published energy-per-query
literature with real efficiency differences between an older large
monolithic model and current optimized serving. Treat HIGH as a
deliberately conservative (i.e., large) upper bound, not as an equally
likely outcome to CENTRAL. - The small-model energy discount (1/10) is conservative by design. The
literature datapoint most directly comparable (Luccioni et al.'s
BLOOM-176B vs. 7B comparison) suggests up to ~40x; we use 10x because
MLPerf scaling data and production batching/quantization gains compress
the practical gap, and because using a smaller discount than the
literature maximum keeps this estimate on the conservative side. - PUE is applied once, correctly scoped. The Google frontier figure is
facility-inclusive already; the Luccioni-derived HIGH-scenario figure is
IT-load-only and has an explicit PUE multiplier applied. Conflating the
two — e.g. applying a PUE multiplier to the already-inclusive Google
figure — would double-count facility overhead. - Results are grid-mix and serving-configuration dependent. Batching,
quantization, and the operator's actual PUE can each shift outcomes by
tens of percent in either direction; the scenarios above bracket a
plausible range rather than pin down a single true value. - Prompt-length assumption. The 750-token midpoint (500–1,000 band) used
to convert Google's per-prompt figure to a per-token figure is an
assumption, not a measurement of Elis's own traffic mix.
5. Caveats
The 80% and 44.8% figures are measured token ratios from our own platform —
the 80% figure from one real production account over 30 days (reported, not
projected); the 44.8%-fewer-tokens / 1.8x quota-runway figure from 508 of
our own platform plans (p50 1.73x, max 2.76x). All energy and
carbon-intensity factors are external published estimates, not our
measurements (Google, Epoch AI, OpenAI-stated, Luccioni et al. FAccT 2024,
IEA 2025, Uptime Institute 2025). Estimates are inference-only: they exclude
training-run amortization and embodied hardware carbon — embodied
(manufacturing/hardware) carbon adds an estimated 10–30% on top of
operational emissions depending on server lifespan; the cited Nature
Scientific Reports study applies a conservative 2x multiplier to operational
emissions as a bounding assumption (Nature Scientific Reports, 2024) — so
total footprints are higher than inference-only figures. Results are
grid-mix and serving-configuration dependent (batching, quantization
technique, and PUE shift outcomes by tens of percent), and published
energy-per-query estimates span 5–20x by methodology — hence ranges rather
than a point estimate. Water usage is not standardized across sources and is
not estimated here. Cost figures do not transfer from token ratios: in our
first controlled benchmark, estimated model cost fell 36.3% while visible
token volume rose 40.7%. No dollar figure is used in this CO2e calculation.
The per-tier breakdowns in §2 are illustrative, built on conservative
assumed energy ratios, not a measured production tier mix; this document
will be updated when the measured distribution is available.
6. References
- Elkin et al., "Measuring the environmental impact of AI inference," arXiv:2508.15734 (Aug 2025). https://arxiv.org/abs/2508.15734
- Google Cloud, "Measuring the environmental impact of AI inference." https://cloud.google.com/blog/products/infrastructure/measuring-the-environmental-impact-of-ai-inference
- Epoch AI, "How much energy does ChatGPT use?" https://epoch.ai/gradient-updates/how-much-energy-does-chatgpt-use
- Luccioni, Jernite, Strubell, "Power Hungry Processing: Watts Driving the Cost of AI Deployment?" FAccT 2024, arXiv:2311.16863. https://arxiv.org/abs/2311.16863
- IEA, "Electricity 2026" (emissions). https://www.iea.org/reports/electricity-2026/emissions
- Ember, "US Electricity 2025 Special Report." https://ember-energy.org/latest-insights/us-electricity-2025-special-report/
- Google, "Efficiency — Data Centers." https://datacenters.google/efficiency/
- Uptime Institute, 2025 Global Data Center Survey (PUE). https://uptimeinstitute.com
- Nature Scientific Reports, "Embodied carbon and AI hardware lifecycle" (2024). https://www.nature.com/articles/s41598-024-76682-6
- "Energy-efficient inference serving via batching" analysis. https://arxiv.org/pdf/2505.09598
- "Quantization for efficient LLM inference" analysis. https://arxiv.org/pdf/2410.12032
- US EPA, "Greenhouse Gas Emissions from a Typical Passenger Vehicle." https://www.epa.gov/greenvehicles/greenhouse-gas-emissions-typical-passenger-vehicle